page 1 www.citrelay.com phone - 763.535.2339 fax - 763.535.2194 speci? cations and availability subject to change without notic e. dimensions shown in mm. dimensions are shown for reference purp oses only. rohs compliant j114fl 29.24 x 13.15 x 15.7 mm ? switching capacity 16a ? produced in accordance to iec 60335-1 ? pc board mounting ? ul/cul certi? ed coil voltage vdc coil resistance +/- 10% pick up voltage vdc (max) 75% of rated voltage release voltage vdc (min) 10% of rated voltage coil power w operate time ms release time ms rated max 5 6.5 62 3.75 .5 .41 10 5 6 7.8 90 4.50 .6 9 11.7 202 6.75 .9 12 15.6 360 9.00 1.2 24 31.2 1440 18.00 2.4 48 62.4 5760 36.00 3.6 coil data* e197851 contact arrangement 1a = spst n.o. 1c = spdt 2a = dpst n.o. 2c = dpdt contact rating 12a @ 250vac; 30 vdc, general purpose, 85c 16a @ 250vac; 30vdc, general purpose, 85c 8a @ 277vac; 30vdc, general purpose, 85c contact resistance < 50 milliohms initial contact material agsno 2 maximum switching power 480w, 4000va maximum switching voltage 380vac, 110vdc maximum switching current 16a contact data* general data* electrical life @ rated load 100k cycles, average mechanical life 10m cycles, average insulation resistance 100m min. @ 500vdc initial dielectric strength, coil to contact 5000v rms min. @ sea level initial contact to contact 1000v rms min. @ sea level initial shock resistance 500m/s 2 for 11 ms vibration resistance 1.50mm double amplitude 10~40hz operating temperature -55 o c to +105 o c storage temperature -55 o c to +155 o c solderability 260 o c for 5 s weight 14g features e * values can change due to the switching frequency, desired reli- ability levels, environmental conditions and in-rush load levels. it is recommended to test actual load conditions for the application. it is the user?s responsibility to determine the performance suitability for their speci c application. the use of any coil voltage less than the rated coil voltage may compromise the operation of the relay.
www.citrelay.com phone - 763.535.2339 fax - 763.535.2194 speci? cations and availability subject to change without notic e. dimensions shown in mm. dimensions are shown for reference purp oses only. j114fl page 2 dimensions - 12amp single pole units = mm 7.50 [.30] 20.00 [.79] 2.70 [.11] 2.70 [.11] 3.50 [.14] 0.55 typ [.02] 0.80 typ [.03] 3.25 typ [.13] 29.05 [1.14] 12.90 [.51] 16.10 [.63] (2x) 0.45 [.02] (2x) 0.60 [.02] 3.50 [.14] ordering information 1. series j114fl 1c s 16 12vdc .41 j114fl 2. contact arrangement 1a = spst n.o. 1c = spdt 2a = dpst n.o. 2c = dpdt 3. sealing option s = sealed 4. contact rating 12 = 12a **only available with 1 pole relays 16 = 16a **only available with 1 pole relays 8 = 8a **only available with 2 pole relays 5. coil voltage 5vdc 6vdc 9vdc 12vdc 24vdc 48vdc 6. coil power .41 = .41w
www.citrelay.com phone - 763.535.2339 fax - 763.535.2194 speci? cations and availability subject to change without notic e. dimensions shown in mm. dimensions are shown for reference purp oses only. page 3 j114fl bottom views schematics & pc layouts 20.00 [.79] 3.50 [.14] 7.50 [.30] ?1.30 typ [.05] 20.00 [.79] 3.50 [.14] 3.50 [.14] 7.50 [.30] ?1.30 typ [.05] 1a (12amp) 1c (12amp) dimensions - 16amp single pole, 8amp double pole units = mm 20.00 [.79] 5.00 [.20] 2.76 [.11] 2.70 [.11] 7.50 [.30] 0.55 typ [.02] 0.80 typ [.03] 29.15 [1.15] 12.90 [.51] 16.00 [.63] 3.25 typ [.13] 5.00 [.20] (2x) 0.60 [.02] (2x) 0.45 [.02]
www.citrelay.com phone - 763.535.2339 fax - 763.535.2194 speci? cations and availability subject to change without notic e. dimensions shown in mm. dimensions are shown for reference purp oses only. page 4 j114fl bottom views schematics & pc layouts 20.00 [.79] 5.00 [.20] 7.50 [.30] ?1.30 typ [.05] 20.00 [.79] 5.00 [.20] 5.00 [.20] 7.50 [.30] ?1.30 typ [.05] 1a (16amp) 1c (16amp) 20.00 [.79] 5.00 [.20] 7.50 [.30] ?1.30 typ [.05] 20.00 [.79] 5.00 [.20] 7.50 [.30] 5.00 [.20] ?1.30 typ [.05] 2a (8amp) 2c (8amp)
|